Skip to content
Heating Problems

Heater Not Working? What to Check First

Heater not working on a cold Melbourne night? Many heater problems come down to something simple: a controller setting, a tripped circuit, the gas turned off or a blocked filter. Here are the safe checks to try first for gas ducted heaters, space heaters and wall furnaces, what each symptom usually means, and when to stop and call a licensed gas fitter.

  • Free fixed quote before any work
  • Licensed gas and refrigerant techs
  • Every Melbourne suburb
  • Licensed Technicians
  • 24/7 Emergency Callouts
  • Upfront Fixed Pricing
  • All Melbourne Suburbs
  • Same-Day Repairs

Common signs

What's your heater doing?

  • Won't turn on at all
  • Fan runs but the air is cold
  • Clicks but won't light
  • Lights, then shuts off
  • Code or flashing light on the controller
  • Some rooms warm, others cold

If you smell gas at any point, stop. Turn off the gas at the meter, don't use switches near the smell, and call the gas emergency line on your gas bill.

Five safe checks to try first

These checks are safe for anyone and fix a surprising number of heater callouts. Don't remove panels or touch gas parts yourself.

Two Braemar wall controllers for a heating and cooling system, one showing 13 degrees
Check the controller first: mode, set temperature and any code on the screen.
  • Controller: check it's set to Heat, the set temperature is above the room temperature, and no timer or schedule is overriding it. Replace the batteries if it has them.
  • Power: check the heater's power point is on and the circuit breaker hasn't tripped. A ducted heater has its own power point next to the unit.
  • Gas: check the gas is on at the meter, and that your cooktop or other gas appliances light.
  • Filter and vents: clean the return air filter on a ducted system, or the filter on a space heater, and make sure vents and grilles aren't blocked.
  • One reset: turn the heater off at the power point for five minutes, then back on. If it locks out again, leave it off.

Only reset once. A heater that keeps shutting down is protecting itself, and repeated resets can make a gas fault worse.

What each symptom usually means

If the checks above don't fix it, the symptom points to the likely fault. This table covers the problems we see most on gas heaters in Melbourne.

Heater symptoms and their usual causes
SymptomUsual causeWhat to do
Won't turn on, controller blankNo power, a tripped circuit or a failed controllerCheck the power point and breaker, then call
Fan runs, air is coldBurner not lighting: igniter, flame sensor or gas valveCheck the gas is on, then book a repair
Clicks but won't lightWorn igniter, dirty flame sensor or no gasBook a repair
Lights, then shuts offDirty flame sensor or overheating from a blocked filterClean the filter, reset once, then call
Pilot won't stay litWorn thermocouple on an older heaterSee our gas heater pilot light guide, then book a repair
Some rooms coldZone closed, a zone motor fault or a disconnected ductCheck the zones are on, then call
Smell, soot or yellow flamePoor combustion or a blocked flueSwitch off now and book a CO test

Ducted heating not working

Gas ducted heating has more to go wrong than a wall heater, because the heat is made in one place and carried through the roof to every room. So the first question is whether the whole house is cold or just part of it.

If the whole house is cold, the heater itself has stopped: it isn't lighting, it's locked out on a fault, or the controller isn't calling for heat. Listen at the unit, which is in the roof space, under the floor or on an outside wall. A fan running with no burner means an ignition or gas fault. Nothing at all points to power, the controller or a failed board. Most brands show a code on the wall controller, and Brivis has its own reset sequence.

If only one room or one end of the house is cold, the heater is usually fine and the air isn't getting there. A zone switched off on the controller, a zone motor that has failed shut, a duct that has come off its outlet, or a crushed duct after work in the roof are the usual causes. Look up at the ceiling outlet: weak or no airflow from one vent while others blow strongly is the giveaway.

Flexible ducts and zone motors in a ceiling space above a Melbourne home
Zone motors and ducts in the roof. A stuck motor or a duct that has dropped off leaves one room cold.
  • Whole house cold, fan runs: ignition, flame sensor or gas valve
  • Whole house cold, nothing runs: power, controller or control board
  • One room cold: zone off, zone motor failed or a duct disconnected
  • Weak airflow everywhere: blocked return air filter or a failing fan motor

Brand-specific help

Most ducted heaters in Melbourne are Brivis, Braemar or Bonaire, and each shows faults a little differently. If your controller shows a code, write it down with the heater's model and tell us when you book. Our Brivis heater reset guide has step-by-step reset instructions, and our brand pages cover the common faults for Brivis, Braemar, Rinnai and Vulcan.

If the heater still won't work after the safe checks, book a repair. A licensed gas fitter can usually find the fault within the first visit, and we give you a free fixed quote before any repair starts.

Why choose us

Still not working? we can help

Licensed gas fitters who repair every common heater brand in Melbourne.

Licensed Gas Fitters

Every heater repair is done by licensed gas fitters, with a carbon monoxide test.

Free Fixed Quote

We find the fault and quote the repair before any work starts.

Tell Us the Symptom

The symptom and any code help us bring the likely part first time.

How it works

Sorted in four simple steps

No run-around and no surprises, from your first call to a system that works again.

  1. Step 1

    Call or book online

    Tell us what's wrong. Call 0405 133 761 any hour, or book online in a minute.

  2. Step 2

    We come to you

    A licensed technician arrives when we say, with parts for the major brands on board.

  3. Step 3

    Fixed quote first

    We find the fault and you approve the price before any work starts. No call-out fee.

  4. Step 4

    Fixed and tested

    We test the system, tidy up and explain what we did, backed by our 100% satisfaction guarantee.

Heater died? Aircon blowing warm? Don't wait it out.

Melbourne weather doesn't wait — neither do we. Day or night, a licensed technician is one call away.

FAQ

Frequently asked questions

Common questions when a gas heater stops working.

The fan is running but the burner isn't lighting. Check the gas is on at the meter and the controller is set to Heat. If it still blows cold, the usual causes are a worn igniter, a dirty flame sensor or a gas valve fault, which need a licensed gas fitter.

Get your free quote in minutes

Tell us what you need and we'll come back with an upfront fixed price — usually the same day. No obligation, no pushy sales.

Your details stay with us — never shared.