Is it the controller or the heater?
The wall controller is the part you see, so it often gets the blame. In practice, a controller fault, a damaged cable between the controller and the heater, and a failed control board in the heater can all look the same from the hallway. Replacing the controller without testing first can mean paying for a part that doesn't fix anything.
We start at the controller, check the voltage and signal reaching it, then test the cable run through the roof and the heater's own board. Only then do we tell you which part has failed and what it takes to fix it.
| Symptom | Usual cause | What to do |
|---|---|---|
| Screen completely blank | No power at the heater, a tripped circuit or a broken cable | Check the heater's power point and switchboard, then call |
| Code returns after every reset | A real heater fault the controller is reporting | Note the code and book a heater repair |
| Temperature reads too high or low | Faulty sensor in the controller, or it's in a draught or sunlight | Book a check; a sensor or relocation fixes it |
| Buttons or touch screen dead | Worn keypad, failed screen or water damage | Book a repair or replacement |
| Controller works, heater doesn't start | Communication fault in the cable or the heater's board | Book a repair; don't keep cycling the power |
| Some zones never open | Zone motor or zone module fault | Book a repair |
If you smell gas near the heater or the controller shows a gas or flame fault more than once, turn the heater off and call us. Don't keep resetting it.