Reverse Cycle Aircon Not Heating

When a reverse cycle aircon is not heating on a cold Melbourne morning, it isn't always broken. Hot start, defrost cycles and Auto mode all make a healthy system look faulty for a few minutes at a time. Real faults do happen, though: a stuck reversing valve, a failed sensor, a refrigerant leak or an outdoor unit that won't start. This page explains which is which, what you can safely check, and when to book a repair. It covers split, multi-head and ducted reverse cycle systems of every brand. For gas ducted heaters, see our heater not working page.

  • Free fixed quote before any work
  • Licensed gas and refrigerant techs
  • Every Melbourne suburb
  • Licensed Technicians
  • 24/7 Emergency Callouts
  • Upfront Fixed Pricing
  • All Melbourne Suburbs
  • Same-Day Repairs

What we see

How a reverse cycle system fails to heat

  • Blows cold air on Heat
  • Warm, but the room never gets warm
  • Stops and flashes a light every so often
  • Outdoor unit iced up and not clearing
  • Takes ages to start blowing
  • Cools fine but won't heat

Thick ice that stays on the outdoor unit, a burning smell, or a breaker that trips: switch off at the breaker and call us.

First, rule out the normal winter behaviour

Reverse cycle heating works by pulling heat out of the outside air and pumping it indoors. That design has two habits that worry people every June. The first is hot start: when you switch to Heat, the indoor fan waits until the coil is warm before it blows, so nothing seems to happen for two to five minutes.

The second is defrost. When it's below about 7 degrees and damp, frost builds on the outdoor coil. Every 30 to 90 minutes the system reverses for a few minutes to melt it. Inside, the fan stops and a light may flash. Outside, the fan stops and the unit steams. Both are normal. What isn't normal is a defrost that never finishes, or ice that keeps building into a solid block.

Checks you can do before calling

Work through these in order. Most take a minute or two.

  • Mode shows the sun symbol for Heat, not Auto, Cool or Dry
  • Set temperature is above the room temperature, say 22 for a test
  • On a ducted system, the wall controller isn't locked to cooling and the zones are open
  • Filters are clean: a blocked filter makes the coil overheat and the unit cut back
  • Outdoor unit has power, clear space around it, and no snow-like ice packed into the fins
  • No error code on the display. If there is one, note it for the technician

Never chip ice off the outdoor coil or pour boiling water on it. The aluminium fins bend and tear easily.

Faults that stop a reverse cycle aircon heating

When the checks don't help, the symptom narrows it down. These are the faults we find most on Melbourne homes in winter.

Mitsubishi Electric reverse cycle outdoor units on a flat roof
Reverse cycle outdoor units on a roof. In heating mode, they're the part doing the work.
Aircon not heating: symptoms and usual causes
SymptomUsual causeFix
Cools fine, blows cold on HeatReversing valve or its solenoid coilValve coil or valve replaced
Warm air but weak, room never warmsLow refrigerant from a leakLeak repair and recharge
Outdoor coil stays a block of iceDefrost sensor or control board faultSensor or board replaced
Outdoor fan won't startFan motor or capacitorPart replaced, often same visit
Heats for a minute then stops, with a codeTemperature sensor or communication faultFault traced from the code
Ducted: warm in some rooms onlyZone motor, damper or disconnected ductDucted repair

Brand-specific heating faults

Mitsubishi Electric and Daikin are the two brands most searched for heating problems in Australia. Both show a code or a pattern of flashing lights when they detect a fault, which tells us where to start before we arrive. Our brand pages list the common ones. We repair reverse cycle systems from Fujitsu, Panasonic, Samsung, LG, Toshiba, Hitachi, ActronAir and every other major brand too.

Why choose us

Why call us when the heating stops

Tested before replaced

We confirm which part has failed before we fit anything, then give you a fixed quote.

ARCtick-licensed

Reversing valves and leak repairs mean opening the refrigerant circuit. We're licensed to do it.

Common parts in the van

Capacitors, sensors and fan motors travel with us, so many winter repairs finish on the first visit.

How it works

Sorted in four simple steps

No run-around and no surprises, from your first call to a system that works again.

  1. Step 1

    Call or book online

    Tell us what's wrong. Call 0405 133 761 any hour, or book online in a minute.

  2. Step 2

    We come to you

    A licensed technician arrives when we say, with parts for the major brands on board.

  3. Step 3

    Fixed quote first

    We find the fault and you approve the price before any work starts. No call-out fee.

  4. Step 4

    Fixed and tested

    We test the system, tidy up and explain what we did, backed by our 100% satisfaction guarantee.

Heater died? Aircon blowing warm? Don't wait it out.

Melbourne weather doesn't wait — neither do we. Day or night, a licensed technician is one call away.

FAQ

Frequently asked questions

Common questions about a reverse cycle aircon that won't heat.

For the first few minutes that's deliberate. Most systems hold the indoor fan off, or run it very slowly, until the coil is warm, so you don't get a cold draught. This is often called hot start or cold draft prevention. If it's still blowing cold after ten minutes on Heat, something is wrong.

Get your free quote in minutes

Tell us what you need and we'll come back with an upfront fixed price — usually the same day. No obligation, no pushy sales.

Prefer to talk?0405 133 761— 24/7

Your details stay with us — never shared.