Why does my aircon smell?
Every time your aircon cools, water condenses on the indoor coil and runs into a drain tray. The fine dust that gets past the filters sticks to that wet coil and to the fan barrel, the long roller of blades that pushes air into the room. Warm, damp and dusty is exactly what mould and bacteria need. After a season or two, they form a grey or black film, and the fan blows their smell into the room every time the unit starts.
Other smells have other causes: an overheating electrical part, a blocked drain holding stale water, an animal that has died in the ducts, or a smell in the house that the aircon is simply moving around. The table below matches the smell to the usual cause.
| Smell | Usual cause | How urgent |
|---|---|---|
| Musty, damp, mouldy | Mould on the coil, fan barrel or drain tray | Not urgent. Book a clean |
| Sour, like vinegar | Bacteria in a wet drain tray or on the coil | Not urgent. Clean and drain flush |
| Like dirty socks | Bacteria on the coil, often when it rarely dries | Not urgent. Book a clean |
| Fishy | Overheating plastic or wiring insulation | Urgent. Switch off at the breaker |
| Burning or electrical | Overheating motor, capacitor, wiring or board | Urgent. Switch off at the breaker |
| Rotten, like a dead animal | A rodent or bird in the ducts or outdoor unit | Soon. Don't run it until it's found |
| Like urine or ammonia | Bacteria in the drain, or pet urine near a return air grille | Not urgent. Clean, and check the room |
| Rotten eggs | A natural gas leak in the house, not the aircon | Emergency. See the note below |
A rotten egg smell is natural gas, not your air conditioner. Leave the house, don't use switches or phones near the smell, and call the gas emergency line on your gas bill from outside.