Window and wall unit repairs
A window or through-the-wall air conditioner holds the whole system in one box: compressor, both coils, a single fan motor driving two fans, and a drain tray. Because everything is together, faults are usually quick to find. The most common are a failed capacitor or fan motor, a dirty coil, a worn thermostat or switch, and water leaking because the unit has settled and now tilts towards the room.
We test the unit where it's installed, so we can also check the seal around the frame, the angle it sits at and the power supply. If the compressor has failed or the coil is leaking refrigerant on an old unit, we'll say so and help you weigh up a repair against a replacement.
| Symptom | Usual cause | Usual fix |
|---|---|---|
| Fan runs, no cold air | Failed capacitor or compressor, low refrigerant | Replace the capacitor, or test and quote the compressor |
| Water dripping inside | Unit tilted towards the room, blocked drain | Re-level the unit and clear the drain |
| Ice on the front coil | Dirty filter or coil, low refrigerant | Clean the coil, find and fix any leak |
| Rattling or grinding | Loose panel, worn fan motor bearings | Tighten panels or replace the motor |
| Hums but won't start | Failed start capacitor | Replace the capacitor |