What goes wrong with a portable aircon
A portable works like a small split system folded into one cabinet. Room air passes over a cold coil at the front, while a second fan pulls air over a hot coil at the back and pushes that heat out through the exhaust hose. The water the cold coil collects goes into a tank, or it's sprayed onto the hot coil and leaves with the exhaust air.
Because everything is packed so close together, a single blocked part affects the rest. A clogged rear filter makes the hot coil overheat, and the compressor then cuts out. A squashed hose pushes hot air back into the room. A stuck float switch tells the unit the tank is full and stops it cooling. This table shows what we find most often.

| What you notice | Usual cause | Check it yourself? |
|---|---|---|
| Blowing air but not cold | Blocked filters, dirty coil, or a long or kinked exhaust hose | Yes. Clean the filters and straighten the hose |
| Cools, then cuts out | Hot coil overheating, a failing compressor or a faulty sensor | Partly. Clear the rear grille, then call |
| Full-tank light with an empty tank | Stuck or failed float switch | No. The switch needs testing |
| Water on the floor | Tank overflowing, loose drain plug or a failed internal pump | Yes. Check the plug and empty the tank |
| Loud rattle or grinding | Loose panel, worn fan motor bearings or debris in the fan | No. Switch off and call |
| Won't turn on | Tripped safety switch, damaged cord or a failed control board | Check the power point first |
| Ice on the front coil | Very dirty filter or low refrigerant | Clean the filter, then call if it returns |